The Initial Calibration (READ BEFORE USING THE SYSTEM):
Make sure the driveshaft speed sensor is installed and functioning correctly.
Disable the Torque Management system w/
ETM_Disable. Make sure the box titled “Torque
Control Enable”, in the Torque Parameters table is not checked. See Torque Parameters screen
print above.
Following the “How to Use the ETM System procedure directly above, collect data from a pass.
In the Desired_Driveshaft_Table, input desired driveshaft speed values 200 RPM greater than
the actual driveshaft speed data collected in the initial pass.
Interpreting ETM Replay Graphs
Timer enable
“on” starts the
timers.
User inputted
TISS curve
Actual driveshaft
speed or TOSS
value
Rev 1.1